:TRIGger:M1553:RTA

Command Syntax
:TRIGger:M1553:RTA <value>
<value> ::= 5-bit integer in decimal, <nondecimal>, or
<nondecimal> ::= #Hnn where n ::= {0,..,9|A,..,F}
<string> ::= "0xnn" where n::= {0,..,9|A,..,F}
The :TRIGger:M1553:RTA command sets the Remote Terminal Address
(RTA) to trigger on if the trigger type has been set to RTA using the
:TRIG:M1553:TYPE command.
Query Syntax
:TRIGger:M1553:RTA?
The :TRIGger:M1553:RTA? query returns the current TV trigger line
number setting.
Return Format
<value><NL> in nondecimal format
See Also
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
(see
page
786)
<string> from 0-31
"Introduction to :TRIGger Commands"
":TRIGger:M1553:TYPE"
on page 467