5
Commands by Subsystem

:BLANk

Command Syntax
:BLANk [<source>]
<source> ::= {CHANnel<n> | FUNCtion | MATH | SBUS} for the DSO models
<source> ::= {CHANnel<n> | DIGital0,..,DIGital15 | POD{1 | 2}
<n> ::= {1 | 2 | 3 | 4} for the four channel oscilloscope models
<n> ::= {1 | 2} for the two channel oscilloscope models
The :BLANk command turns off (stops displaying) the specified channel,
digital pod, math function, or serial decode bus. The :BLANk command
with no parameter turns off all sources.
To turn on (start displaying) a channel, etc., use the :VIEW command. The DISPlay
N O T E
commands, :CHANnel<n>:DISPlay, :FUNCtion:DISPlay, :POD<n>:DISPlay, or
:DIGital<n>:DISPlay, are the preferred method to turn on/off a channel, etc.
MATH is an alias for FUNCtion.