:TRIGger:I2S:ALIGnment

Command Syntax
:TRIGger:I2S:ALIGnment <setting>
<setting> ::= {I2S | LJ | RJ}
The :TRIGger:I2S:ALIGnment command selects the data alignment of the
I2S bus for the serial decoder and/or trigger when in I2S mode:
• I2S — standard.
• LJ — left justified.
• RJ — right justified.
Note that the word select (WS) polarity is specified separately with the
:TRIGger:I2S:WSHigh command.
Query Syntax
:TRIGger:I2S:ALIGnment?
The :TRIGger:I2S:ALIGnment? query returns the currently selected I2S data
alignment.
Return Format
<setting><NL>
<setting> ::= {I2S | LJ | RJ}