The following trigger types are available (see
page 473).
• CAN (Controller Area Network) triggering— will trigger on CAN
The CAN and LIN serial decode option (Option ASM) replaces the functionality that was
N O T E
available with the N2758A CAN trigger module for the 54620/54640 Series oscilloscopes.
• Edge triggering— identifies a trigger by looking for a specified slope
• Nth Edge Burst triggering— lets you trigger on the Nth edge of a burst
• Pulse width triggering— (:TRIGger:GLITch commands) sets the
• Pattern triggering— identifies a trigger condition by looking for a
• Duration triggering— lets you define a pattern, then trigger on a
• FlexRay triggering— will, when used with a BusDoctor 2 protocol
• I2S (Inter- IC Sound or Integrated Interchip Sound bus) triggering—
• IIC (Inter- IC bus) triggering— consists of connecting the oscilloscope
• LIN (Local Interconnect Network) triggering— will trigger on LIN sync
• MIL- STD 1553 triggering (with Option 553) — lets you trigger on
468
version 2.0A and 2.0B signals. Setup consists of connecting the
oscilloscope to a CAN signal. Baud rate, signal source, and signal
polarity, and type of data to trigger on can be specified. With the
automotive CAN and LIN serial decode option (Option ASM), you can
also trigger on CAN data and identifier patterns, set the bit sample
point, and have the module send an acknowledge to the bus when it
receives a valid message.
and voltage level on a waveform.
that occurs after an idle time.
oscilloscope to trigger on a positive pulse or on a negative pulse of a
specified width.
specified pattern. This pattern is a logical AND combination of the
channels.
specified time duration.
analyzer and a four- channel mixed- signal oscilloscope with Option FRS,
trigger on FlexRay bus frames, times, or errors.
consists of connecting the oscilloscope to the serial clock, word select,
and serial data lines, then triggering on a data value.
to the serial data (SDA) line and the serial clock (SCL) line, then
triggering on a stop/start condition, a restart, a missing acknowledge, or
on a read/write frame with a specific device address and data value.
break at the beginning of a message frame. With the automotive CAN
and LIN serial decode option (Option ASM), you can also trigger on
Frame IDs.
MIL- STD 1553 serial data.