7
Obsolete and Discontinued Commands

:DISPlay:ORDer

Query Syntax
:DISPlay:ORDer?
The :DISPlay:ORDer? query returns a list of digital channel numbers in
screen order, from top to bottom, separated by commas. Busing is
displayed as digital channels with no separator. For example, in the
following list, the bus consists of digital channels 4 and 5: DIG1, DIG4
DIG5, DIG7.
The :DISPlay:ORDer command is an obsolete command provided for compatibility to
N O T E
previous oscilloscopes. This command is only available on the MSO models.
Return Format
<order><NL>
<order> ::= Unquoted ASCII string
A return value is included for each digital channel. A return value of NONE indicates that a
N O T E
channel is turned off.
See Also
Example Code
Example program from the start:
page 812
700
(see
page
786)
":DIGital<n>:POSition"
' DISP_ORDER - Set the order the channels are displayed on the
' analyzer.
You can enter between 1 and 32 channels at one time.
' If you leave out channels, they will not be displayed.
' Display ONLY channel 0 and channel 10 in that order.
myScope.WriteString ":DISPLAY:ORDER 0,10"