5
Commands by Subsystem

:TRIGger:FLEXray:FRAMe:TYPE

Command Syntax
:TRIGger:FLEXray:FRAMe:TYPE <frame_type>
<frame_type> ::= {NORMal | STARtup | NULL | SYNC | NSTArtup | NNULl |
The :TRIGger:FLEXray:FRAMe:TYPE command sets the FlexRay frame type
to trigger on. The frame type setting is only valid when the FlexRay trigger
mode is set to FRAME.
• NORMal — will trigger on only normal (NSTArtup & NNULl & NSYNc)
• STARtup — will trigger on only startup frames.
• NULL — will trigger on only null frames.
• SYNC — will trigger on only sync frames.
• NSTArtup — will trigger on frames other than startup frames.
• NNULl — will trigger on frames other than null frames.
• NSYNc — will trigger on frames other than sync frames.
• ALL — will trigger on all FlexRay frame types.
This command is only valid when the FLEXray triggering and serial decode option (Option
N O T E
FLX) has been licensed.
Query Syntax
:TRIGger:FLEXray:FRAMe:TYPE?
The :TRIGger:FLEXray:FRAMe:TYPE? query returns the current frame type
setting for the FlexRay frame trigger setup.
Return Format
<frame_type><NL>
<frame_type> ::= {NORM | STAR | NULL | SYNC | NSTA | NNUL |
See Also
514
(see
page
786)
NSYNc | ALL}
frames.
NSYN | ALL}
"Introduction to :TRIGger Commands"
":TRIGger:MODE"
on page 473
":TRIGger:FLEXray:TRIGger"
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
on page 467