5
Commands by Subsystem

:TRIGger:FLEXray:FRAMe:CCRepetition

Command Syntax
:TRIGger:FLEXray:FRAMe:CCRepetition <cycle_count_repetition>
<cycle_count_repetition> ::= {ALL | <rep #>}
<rep #> ::= integer from 2-64
The :TRIGger:FLEXray:FRAMe:CCRepetition command sets the repetition
number of the FlexRay cycle count (in the frame header) to trigger on. The
cycle count repetition setting is only valid when the FlexRay trigger mode
is set to FRAME.
This command is only valid when the FLEXray triggering and serial decode option (Option
N O T E
FLX) has been licensed.
Query Syntax
:TRIGger:FLEXray:FRAMe:CCRepetition?
The :TRIGger:FLEXray:FRAMe:CCRepetition? query returns the current
cycle count repetition setting for the FlexRay frame trigger setup.
Return Format
<cycle_count_repetition><NL>
<cycle_count_repetition> ::= {ALL | <rep #>}
<rep #> ::= integer from 2-64
See Also
512
(see
page
786)
"Introduction to :TRIGger Commands"
":TRIGger:FLEXray:TRIGger"
Agilent InfiniiVision 7000A Series Oscilloscopes Programmer's Guide
on page 467
on page 516

Hide quick links: