5
Commands by Subsystem
:SBUS:LIN:PARity
Command Syntax
:SBUS:LIN:PARity <display>
<display> ::= {{1 | ON} | {0 | OFF}}
The :SBUS:LIN:PARity command determines whether the parity bits are
included as the most significant bits (MSB) in the display of the Frame Id
field in the LIN decode bus.
This command is only valid on 4 (analog) channel oscilloscope models when the
N O T E
automotive CAN and LIN serial decode option (Option AMS) has been licensed.
Query Syntax
:SBUS:LIN:PARity?
The :SBUS:LIN:PARity? query returns the current LIN parity bits display
setting of the serial decode bus.
Return Format
<display><NL>
<display> ::= {0 | 1}
Errors
•
See Also
•
•