Issue 1.0
Conditions
Alarm Reports and System Information Reports can be output to a USB stick on the
CD-CP00-AU.
The UNIVERGE SV8100 supports the following Alarms to be output to the LCD of a multiline
terminal:
SMDR Buffer Full
CD-CP00-AU-LAN link Error
The UNIVERGE SV8100 does not support printouts of the following Alarms:
Power Failure
RAM Backup Battery Error
Networking Keep Alive Error
Up to 12 System Alarm times can be scheduled to print on a Monthly, Daily, and Hourly time
frame. The report indicates both Major and Minor Alarms.
System Information Reports cannot be set to output at a scheduled time.
When using the E-mail functionality of reports, the E-mail address in Program 90-11-10
(From Address) must be set for the E-mail feature to work.
After a new alarm is output, it cannot be output a second time. New alarms must be
generated before Program 90-12-04 can be performed a second time.
Up to 100 System Alarm Reports can be stored. When the buffer fills, the oldest record is
deleted to allow the new record to be saved.
If the System is set up to E-mail the Alarm Reports and the Mail Server is down, the report is
not sent.
System Information Reports cannot be set for output via E-mail.
Scheduled Alarm Reports via E-mail prints all alarms. When the system detects New
alarms, this information is output via E-mail on an individual basis.
E-mail Alarm Reports can be sent when each New alarm occurs (Per Event). If you want to
receive complete Alarm Reports periodically, you must specify 12 individual dates and times
in Program 90-24-01 ~ Program 90-24-04 (per period).
A maximum of 99 entries are emailed with the scheduled alarms.
Default Settings
None