To ignore diagnostic test failure on the line module or SRP:
Select the slot number of the slot that you want to ignore diagnostic test failure. This
1.
information is stored on the SRP and is independent of the hardware in the slot. You
can reload a particular slot to boot the module to the operational image.
host1#slot ignore-diagnostic-failure 0
Issue the show environment command to check which line modules are configured
2.
to ignore diagnostics test failure.
host1#show environment
chassis: 14 slot (id 0x5, rev. 0x1)
fabric: 40 Gbps (rev. 0)
fans: fanSubsystemOk
nvs: ok (488MB flash disk, 43% full), matches running config
power: A ok, B not present
srp redundancy: mode is high-availability, state initializing
auto-sync enabled, switch-on-error enabled
sync in progress
slots: ok
online: 0 6 12
standby: 7
empty: 1 2 3 4 5 8 9 10 11 13
diagnostic failure is ignored on slot: 0
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
system operational: yes
Issue the no version of the command to return to the default setting for the slot:
3.
host1(config)# no slot ignore-diagnostic-failure 12
Issue the show environment command to check that the slot no longer ignores
4.
diagnostic test failures :
host1#show environment
fabric: 40 Gbps (rev. 0)
fans: fanSubsystemOk
nvs: ok (488MB flash disk, 43% full), matches running config
power: A ok, B not present
srp redundancy: mode is high-availability, state initializing
auto-sync enabled, switch-on-error enabled
sync in progress
slots: ok
online: 0 6 12
standby: 7
empty: 1 2 3 4 5 8 9 10 11 13
diagnostic failure is ignored on slot: 0,6,7
line redundancy: none
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
chassis: 14 slot (id 0x5, rev. 0x1)