JunosE 11.3.x System Basics Configuration Guide
324
slots: cards missing or offline—Status of each slot
online
standby
offline
empty
line redundancy—Number of redundancy groups installed
width—Number of slots the redundant midplane covers
spare—Slot that contains a spare line module
primary—Slot that contains the primary line module
fabric redundancy—Status of redundancy on the switch fabric on the E120 and E320
routers
ok
none
temperature—Status of the system temperature
timing—Source of the timing signal
primary—Type and status of the primary timing signal
secondary—Type and status of the secondary timing signal
tertiary—Type and status of the tertiary timing signal
auto-upgrade—Status of the auto-upgrade parameter, which enables the system
to revert to a higher-priority timing source after switching to a lower-priority timing
source.
system operational—Status of the system
slot—Number of the slot in which the module resides
type—Type of module in the slot on the E120 and E320 routers
temperature—Temperature of the line module, SRP module, or SFM on the E120
and E320 routers
processor temperature—Temperature of the line module or SRP module
processor temperature status—Temperature condition of the line module
normal—Temperature is in normal range
too hot—Module is too hot; system will go into thermal protection mode if the
temperature of any module exceeds 80° C
Copyright © 2010, Juniper Networks, Inc.