bulkstats collector collect-mode
bulkstats collector description
bulkstats collector interval
bulkstats collector max-size
Copyright © 2010, Juniper Networks, Inc.
Use to assign the data collector.
Example
host1(config)#bulkstats collector 2
Use the no version to delete the collector.
See bulkstats collector.
Use to specify the way the collector retrieves bulk statistics.
Example
host1(config)#bulkstats collector 2 collect-mode auto
Use the no version to specify that either the user or the system will initiate transfers
manually.
See bulkstats collector.
Use to add descriptive information to the bulk statistics file.
Example
host1(config)#bulkstats collector 2 description customer xyz
Use the no version to remove descriptive text from the bulk statistics file.
See bulkstats collector.
Use to specify the time interval in seconds for which the collector transfers data to the
receivers.
Example
host1(config)#bulkstats collector 2 interval 1000
Use the no version to set this time to the default, 360 seconds (6 minutes).
See bulkstats collector.
Use to set the maximum size of the bulk statistics file for all collectors combined. Even
when you configure more than one collector, the first maximum file size configured is
the combined size of all collectors.
The maximum file size that you can configure is 20971520 bytes. However, if you do
not configure a maximum size, then the maximum file size defaults to 5767168 bytes.
Although the CLI accepts the commands, you cannot unconfigure or modify the
configuration of the maximum file size until the router is rebooted.
Example
host1(config)#bulkstats collector 2 max-size 20480
Chapter 4: Configuring SNMP
189
Need help?
Do you have a question about the JUNOSE SOFTWARE FOR E SERIES 11.3.X - SYSTEM BASICS CONFIGURATION GUIDE 2010-10-04 and is the answer not in the manual?