slot accept
Copyright © 2010, Juniper Networks, Inc.
There is no no version.
See adapter erase.
Use to delete the configuration of the module in the selected slot after you install a
different type of module.
This command enables you to create a fresh configuration for the module installed in
the slot.
You can also use this command to accept an empty slot that was previously occupied.
You cannot use this command on a primary SRP module; however, you can use it on
a standby SRP module.
You can use this command only when the state of the module in the slot is not present
or disabled (mismatch).
If you specify a slot on an E120 or E320 router that contains an SRP module, you accept
the configuration of the SC subsystem on that slot by default. You do not, however,
accept the configuration of the fabric slice that resides on the slot.
Use the srp keyword to accept only the configuration of the portion of the SC
subsystem that resides on a specified SRP module.
Use the fabric keyword to accept only the configuration of the fabric slice that resides
on the specified SRP module.
If you specify a slot that contains a line module, you erase the configuration of the line
module and the I/O modules or IOAs associated with it. To erase the configuration of
a specific IOA on the E120 or E320 router, use "adapter accept" on page 356 command.
Depending on the slot's previous configuration, the router might take a few moments
to execute this command.
The following is a sample log message resulting from putting an OC3 line module in a
slot that was previously configured for a line module:
ERROR 02/07/2003 15:16:20 system (slot 3): boardId mismatch: read 0x6 (OC3
dual port without classifier), configured 0x2e (OC12 ATM)
ERX-00-17-04(config)# slot accept
Please wait....
ERX-00-17-04(config)#ERROR 02/07/2003 15:16:31 system (slot 3):
unrecognized board type (0x6)
To resolve the problem, issue the slot accept command for slot 3.
Example 1—Accepts the configuration of the module in slot 3
host1(config)#slot accept 3
Example 2—Accepts the configuration of the specified SRP module and the SC
subsystem in slot 7 (applies only to E120 and E320 routers)
host1(config)#slot accept 7
Example 3—Accepts the configuration of the SC on the SRP module in slot 7 (applies
only to E120 and E320 routers)