JunosE 11.3.x System Basics Configuration Guide
delta-sampling
enable
event
174
host1(config-mgmtevent-trigger)#boolean-test comparison less
Example 2—Specifying a Boolean value to which the test compares
host1(config-mgmtevent-trigger)#boolean-test value 5175438
Example 3—Binding an event to the Boolean-test trigger
host1(config-mgmtevent-trigger)#boolean-test event sysadmin booleanTrigger
Example 4—Setting the trigger to not perform a Boolean test on startup
host1(config-mgmtevent-trigger)#boolean-test startup
Use the no version to delete the Boolean-test values for this trigger or to remove either
the startup condition or event binding.
See boolean-test.
Use to specify delta sampling for the trigger you are configuring.
Example
host1(config-mgmtevent-trigger)#delta-sampling
(Optional) Use the discontinuity-id option to specify a discontinuity MIB ID for the
sample. The discontinuity MIB ID monitors the sample for any discontinuity errors during
the sample frequency. If a discontinuity error occurs, the router removes the sampling
for that interval.
(Optional) Use the discontinuity-id-type option to specify a discontinuity ID type
(either timeStamp or timeTicks). The discontinuity ID type indicates the time value
that you expect for a specific sample.
Use the no version to turn off delta sampling and use absolute sampling (the default).
See delta-sampling.
Use to enable an event configuration or trigger configuration.
Example 1—Event Configuration Mode
host1(config-mgmtevent-event)#enable
Example 2—Trigger Configuration Mode
host1(config-mgmtevent-trigger)#enable
Once enabled, you cannot edit an event or trigger configuration (even when it is
disabled). To change an enabled event or trigger, you must delete it and re-create it.
There is no no version.
See enable.
Copyright © 2010, Juniper Networks, Inc.
Need help?
Do you have a question about the JUNOSE SOFTWARE FOR E SERIES 11.3.X - SYSTEM BASICS CONFIGURATION GUIDE 2010-10-04 and is the answer not in the manual?