too cold—Module is too cold; system will go into thermal protection mode if the
temperature of any module drops below –5° C
IOA temperature—Temperature of the corresponding I/O module or IOA
IOA temperature status—Temperature condition of the corresponding I/O module
or IOA
normal—Temperature is in normal range
too hot—Module is too hot; system will go into thermal protection mode if the
temperature of any module exceeds 80° C
too cold—Module is too cold; system will go into thermal protection mode if the
temperature of any module drops below –5° C
processor temperature ranges—Displays the temperature ranges for the line modules
and SRP modules
IOA temperature ranges—Displays the temperature ranges for the I/O modules on
ERX7xx models, ERX14xx models, and the ERX310 router or IOAs on the E120 and E320
routers
fabric temperature ranges—Displays the temperature ranges for the SRP modules and
SFMs on the E120 and E320 routers
Example 1—Displays the environment of an ERX7xx model
host1#show environment all
chassis: 14 slot (id 0x3, rev. 0x0)
fabric: 5 Gbps (rev. 1)
fans: ok
nvs: ok (81MB flash disk, 54% full)
power: A ok, B not present
AC power: A not present, B not present
srp redundancy: none
*** slots: cards missing or offline
online: 6 9
standby: 8
offline: 2
empty: 0 1 3 4 5 7 10 11 12 13
line redundancy: 1 redundancy group(s)
width 6, spare 8, primary 9
temperature: ok
timing: primary
primary: internal SC oscillator (ok)
secondary: internal SC oscillator (ok)
tertiary: internal SC oscillator (ok)
auto-upgrade enabled
*** system operational: no
processor
temperature
slot
(10C - 70C)
----
-----------
0
31
3
31
5
31
7
31
processor
IOA
temperature
temperature
status
(10C - 70C)
-----------
-----------
normal
30
normal
30
normal
30
normal
30
Chapter 5: Managing the System
IOA
temperature
status
-----------
normal
normal
normal
normal