T1 feed / elevator motor MOT71-002,
–
T2 feed / elevator motor MOT72-001,
–
T3 feed motor MOT73-001,
PL 81.30 Item
–
3 tray transport motor MOT70.025,
–
Tray up limit switch, S73-384,
–
Tray 3 elevate motor, MOT73-002,
•
Repair the wiring as necessary,
REP 1.1
•
If necessary, install a new 3 tray module PWB,
Drum Driver PWB
•
To view the +24V distribution from the
•
For +24V faults on the
drum driver
–
WD 9.1
–
WD 9.2
•
The components that follow are driven from +24V from the
–
Drum fan MOT42-064,
PL 94.20 Item
–
Cleaning unit delivery pump, part of
–
Cleaning unit return reservoir pump, part of
–
Cleaning unit PWB, part of
PL 94.10 Item
•
Repair the wiring as necessary,
REP
•
If necessary, install a new drum driver PWB,
Tray 5 Control PWB
•
To view the +24V distribution from the
•
For +24V faults on the
tray 5 control
–
WD
7.1.
–
WD
7.2.
•
The components that follow are driven from +24V from the
–
Tray 5 transport motor MOT75.018,
–
Elevator motor MOT75-019,
PL 75.68 Item
–
Upper limit switch S75-412,
PL 75.68 Item
–
Tray down limit switch S75-415,
–
Feed motor MOT75-117,
PL 81.40 Item
•
Repair the wiring as necessary,
REP
•
If necessary, install a new tray 5 control PWB,
LCSS PWB
•
To view the +24V distribution from the LCSS power supply module, refer to
•
For +24V faults on the LCSS, refer to:
–
WD 12.1
–
WD 12.3
–
WD 12.4
–
WD 12.5
•
The components that follow are driven from +24V from the
–
Docking interlock switch S12-177,
–
Front door interlock switch S12-303,
Status Indicator RAPs
01H
PL 81.25 Item
22.
PL 81.26 Item
22.
22.
PL 73.16 Item
3.
PL 81.30 Item
25.
PL 73.16 Item
2.
PL 73.16 Item 4
power supply
unit, refer to
WD 1.5
PWB, refer to:
drum driver
PWB:
4.
PL 94.10 Item
21.
PL 94.10 Item
21.
21.
1.1.
PL 1.15 Item
4.
media path driver
PWB, refer to
WD
PWB, refer to:
tray 5 control
PWB:
PL 81.40 Item
2.
4.
12.
PL 75.70 Item
2.
3.
1.1.
PL 75.68 Item
8.
LCSS
PWB:
PL 12.15 Item
2.
PL 12.75 Item
5.
–
Transport motor 1 MOT12-223,
–
SH1 motor MOT12-247, part of
–
SU1 motor MOT12-249, part of
–
Transport motor 2 MOT12-224,
–
Paddle roll motor MOT12-237,
–
Punch head motor MOT12-243,
–
Front tamper motor MOT12-226, part of
–
Rear tamper motor MOT12-227, part of
–
Bin 1 upper limit switch S12-190,
–
Top cover interlock switch S12-197,
–
Bin 1 lower limit switch S12-191,
–
Bin 1 elevator motor MOT12.-241,
•
Repair the wiring as necessary,
•
If necessary, install a new LCSS PWB,
HVF PWB
•
To view the +24V distribution from the HVF power supply module, refer to
•
For +24V faults on the HVF, refer to:
–
WD 12.6
–
WD 12.7
–
WD 12.8
–
WD 12.9
8.4.
–
WD 12.10
–
WD 12.13
–
WD 12.14
–
WD 12.15
•
The components that follow are driven from +24V from the
–
Transport motor 1 MOT12-223,
–
Buffer motor MOT12-262,
–
Nip split motor MOT12-164,
–
Transport motor 2 MOT12-224,
–
BM diverter solenoid SOL12-258,
–
Exit diverter solenoid SOL12-225,
–
Bypass feed motor MOT12-263,
–
Set clamp solenoid SOL12-056,
WD
12.1.
–
Docking interlock switch S12-177,
–
Front door interlock switch S12-303,
–
Top cover interlock switch S12-197,
–
Paddle unit motor MOT12-239,
–
Paddle roll motor MOT12-238, part of
–
Paper pusher motor MOT12-265,
–
Bin 1 elevator motor MOT12-241,
–
Stapler gate safety switch S12-319,
–
Rear tamper motor MOT12-227,
February 2013
2-32
PL 12.40 Item
2.
PL 12.55 Item
5.
PL 12.55 Item
5.
PL 12.60 Item
5.
PL 12.25 Item
10.
PL 12.20 Item
2.
PL 12.45 Item
1.
PL 12.45 Item
1.
PL 12.30 Item
3.
PL 12.75 Item
6.
PL 12.35 Item
1.
PL 12.30 Item
8.
REP
1.1.
PL 12.75 Item
1.
HVF
PWB:
PL 12.120 Item
2.
PL 12.120 Item
1.
PL 12.125 Item
15.
PL 12.120 Item
1.
PL 12.120 Item
4.
PL 12.120 Item
4.
PL 12.120 Item
2.
PL 12.120 Item
4.
PL 12.100 Item
16.
PL 12.115 Item
28.
PL 12.115 Item
24.
PL 12.120 Item
6.
PL 12.115 Item
2.
PL 12.115 Item
13.
PL 12.105 Item
10.
PL 12.115 Item
17.
PL 12.110 Item
19.
ColorQube® 9303 Family
WD
12.6.