*1
Minimum bending radius
■
Mount to the Outside of Control Panel
1.
Use the dimensions in
Figure 2.11 External/Face Mount Enclosure Panel Cut-Out Dimensions
W
22
(0.89)
2.
Remove the keypad and put the keypad connector in the holder on the front cover.
Note:
Insert the end of the keypad connector that has the tab.
A - Keypad
B - Keypad connector
3.
Put the keypad on the outside of the control panel.
Use M3 screws (6 mm (0.2 in) depth cross-recessed pan head screws) to attach the keypad from the
inside. Tighten the screws to a correct tightening torque:
• M3 screws: 0.49 N∙m to 0.73 N∙m (4.34 lbf∙in to 6.46 lbf∙in)
A - Keypad
B - M3 screws
YASKAWA SIEPC71061705H GA700 Series Technical Manual
2.7 Install the Keypad in a Control Panel or Another Device
Figure 2.11
and
Table 2.9
Table 2.9 Panel Cut-Out Dimensions mm (in)
H
W1
78
22
(3.07)
(0.89)
Figure 2.12 Remove the Keypad
Figure 2.13 Mount to the Outside of Control Panel
to cut an opening in the control panel for the keypad.
H1
H2
29
22
(1.14)
(0.89)
C - Holder
C - Enclosure panel
D - Screw mounting holes
H3
d
1
3.6
(0.04)
(0.14)
45