Off control
Requirements:
the relay must have been set up

The PBX will switch off relays with the operating modes Light, Door
opener, Alarm and PC relay after the specified switching duration.

The hold time of the relay will be used. The PBX does not actively
switch off the relay.
Note: As a a pre-requisite, off control must be supported by the relay (for
some relays, e. g. the a/b Switching Modules, switching off cannot be
controlled).
Switching duration
Specifies after how many seconds the PBX will switch off the relay. Possible
entries: 0 to 6000 (0 only for manual relays).
Notes:
The switching duration is used for relays with the operating modes Light,
Door opener, Alarm, PC relay and Manual relay.
To enable the PBX to switch off the relay after the specified switching
duration, off control must be supported by the relay and be switched on
(for some relays, e. g. the a/b Switching Modules, switching off cannot
be controlled). Alternatively, the hold time of the relay can be used.
COMmander 6000/R/RX - Firmware V7.0D - Advanced Information V19 04/2018
Settings – Devices
Relays (Actuators)
777