Circuit Breaker; Residual Current Device (Rcd); Power Connection; Ups (Uninterrupted Power Supply) - Stratasys J826 Site Preparation Manual

Hide thumbs Also See for J826:
Table of Contents

Advertisement

Stratasys J826

Circuit Breaker

A circuit breaker (Type-C) with the following specification is required (subject to the local electrical code).

Residual Current Device (RCD)

The wall outlet must be connected to a residual current device (RCD).

Power Connection

The customer must provide an appropriate power plug and have it installed by a certified electrician.
The following electrical outlets are required:
one outlet behind the printer
three outlets close to the printer (for the workstation, monitor, and servicing equipment)

UPS (Uninterrupted Power Supply)

It is mandatory that the printer is powered through a UPS unit, provided by the customer. This ensures
that—
the quality of printing is not affected by power fluctuations from the mains.
the printer computers can perform a "graceful shutdown" in the event of a power failure.
The UPS specifications are listed below.
©
DOC-18005 Rev. E
Voltage
100–120 VAC
220-240 VAC
2019-2020 Stratasys. All rights reserved.
Table 3 Circuit breaker
Circuit Breaker
15 A or 16 A
10 A
Electrical Requirements