Chapter 2 — Architecture Overview
Expired Cleaning Cartridges When an expired cleaning cartridge is loaded 
into a drive, it is immediately ejected without attempting the cleaning. The 
library flags the cleaning tape as expired and generates system messages to 
notify you of the expired cleaning tape and the failed drive cleaning. It 
marks the cleaning cartridge as expired in its inventory and does not 
attempt to use it for subsequent cleanings. These cartridges have an "x" 
next to the slot number when viewed on the Inventory screen. 
If the cleaning partition contains another, good cleaning cartridge, a 
cleaning that failed because the cleaning cartridge is expired, is 
reattempted the next time the host unloads a data cartridge from the drive. 
MLM Tracking of Cleaning Cartridges When you enable the BlueScale 
Media Lifecycle Management (MLM) feature and use MLM‐enabled 
cleaning cartridges, the library stores usage information, including the 
number of cleans remaining and the cartridge health (good, near expiration 
or expired), in the MLM database. This information is retained in the MLM 
database even when a cleaning cartridge is exported from the library. 
When a cartridge is nearing the end of its useful life, the library notifies you 
so that you can replace the cartridge. This early notification helps prevent 
failed cleanings resulting from using an expired cleaning cartridge.
The library does not store any information about non‐MLM cleaning 
cartridges in the MLM database. However the library does mark an 
expired cleaning cartridge and does not attempt to use it again as long as it 
remains in the library. If an expired non‐MLM cartridge is exported and 
then reimported into the library, it is identified as expired the next time it is 
loaded into a drive.
See Chapter 9 – Configuring and Using Media Lifecycle Management, 
beginning on page 245 for detailed information about MLM.
D
M
RIVE AND
The T950V library's modular design makes it possible to increase media 
capacity or the number of drives in the library to meet storage and 
performance needs as they evolve. Expansion frames can be added to the 
basic single‐frame library for a maximum of eight frames.
As viewed from the front of the library, the main frame must be positioned 
as the left‐most frame. Up to four drive expansion frames can be located 
immediately to the right of the main frame. Media frames can be located to 
the right of the main frame and any drive frames.
August 2019
Note:
TS11xx technology cleaning tapes are always treated as MLM‐