Chapter 7 — Importing and Exporting Cartridges
6. Return to the operator panel and click the appropriate option on the 
Click...
Continue
Override
Stop Exporting
August 2019
Feedback Required screen.
Note:
If you wait more than 10 minutes to respond, the library times 
out and displays a message on the operator panel. The TAP door 
is left open.
If...
You removed the expired cleaning cartridges in the magazines and did not 
replace them with new cartridges. Also click Continue if you removed or 
exchanged the entire magazine. The process continues as follows:
1. The TAP door closes automatically. If you exchanged magazines, the library 
first moves the new magazine into the cleaning partition. It then retrieves the 
next magazine from the cleaning partition and delivers it to the TAP. 
Note:
If you exchanged cartridges and clicked Continue instead of Override, 
click Ok in response to a message stating that the slot containing the exchanged 
cartridge should be empty.
2. The process continues as long as there are magazines with expired cleaning 
cartridges in the cleaning partition or until you click Stop Exporting on the 
Feedback Required screen. Remove the expired cartridges from each 
magazine, place the magazine back into the TAP, and click Continue for each 
one. When there are no expired cleaning cartridges left in the cleaning 
partition, the process stops automatically and the Import/Export TeraPack 
Magazines screen displays.
You exchanged the expired cleaning cartridges in the magazine for new ones. 
The process continues as follows:
1. The TAP door closes automatically. The library moves the magazine in the 
TAP back to the cleaning partition. It then retrieves the next magazine from 
the cleaning partition and delivers it to the TAP. 
2. The process continues as long as there are magazines with expired cleaning 
cartridges in the cleaning partition or until you click Stop Exporting on the 
Feedback Required screen. Exchange the expired cartridges in each 
magazine, place the magazine back into the TAP, and click Override for each 
one. When there are no expired cleaning cartridges left in the cleaning 
partition, the process stops automatically and the Import/Export TeraPack 
Magazines screen displays.
The expired cleaning cartridge you removed or exchanged is the last one you 
want to process.
Exporting or Exchanging Magazines and Cartridges
User Guide—Spectra T950V Library
217