Chapter 4 — Configuring the Library
5. Click Next. The Utilities screen refreshes to show a list of the advanced 
6. Select the Modify Barcode Reporting utility. The screen refreshes to show 
7. Change the barcode reporting as required for your environment.
Use this parameter
Non-check-
summed barcodes
Check-summed
barcodes
Ignore check-sum
barcodes
August 2019
utilities. 
information about the utility. Figure 57 shows the default settings. 
Figure 57 Use the Modify Barcode Reporting utility to change
how the library handles barcode labels.
If...
Your labels do not include a checksum. 
Your labels include a checksum and you want the barcode verified against the 
checksum when it is read. Verification is not generally required, but adds extra 
confirmation that the barcode label was read correctly by the barcode reader.
Your labels include a checksum character but you do not want the barcode 
verified against the checksum when it is read. This is the default setting.
Configuring Optional Library Settings