Chapter 4 — Configuring the Library
Setting
Auto Logout
Timeout
Disable Online
Access to Spectra
Logic
Enable Drive
Performance
Monitoring
Enable Power
Consumption
Monitoring
Enable Automatic
Power-Up After
Power Failure
August 2019
Description
Set how long the current connection to the BlueScale user 
interface is idle before the current user is logged out.
1. Enter the number of minutes for the timeout.
2. Click Save.
Note:
Setting the timeout value to zero disables auto 
logout.
Disable or enable displaying links to the Spectra Logic 
website at the bottom of each BlueScale screen when the 
library has a connection to the Internet.
1. Select the Disable Online Access to Spectra Logic check box 
to disable the option (or clear the check box to enable it).
2. Click Save.
Enable or disable the option to monitor the performance of 
the drives in the library (see View Drive Performance 
Statistics on page 150).
CAUTION:
Make sure that the drives do not contain
media before you enable or disable Drive Performance
Monitoring. If you enable or disable this option when a
drive contains a cartridge, the drive is reported as empty
and backups may fail.
1. Select the Enable Drive Performance Monitoring check box 
to enable the option (or clear the check box to disable it).
2. Click Save.
Enable or disable the option to monitor the amount of 
power your library is using through the Power 
Consumption Monitor (EnergyAudit) feature (see View 
Power Consumption Statistics on page 152).
1. Select the Enable Power Consumption Monitoring check box 
to enable the option (or clear the check box to disable it).
2. Click Save.
Note:
When you disable and then re‐enable power 
consumption monitoring, the library does not begin 
capturing data again until you power cycle the library.
Enable or disable the option to automatically power on the 
library after a power failure (see Use the Automatic Power‐
Up After Power Failure Feature on page 143).
1. Select the Enable Automatic Power-Up After Power Failure 
check box to enable the option (or clear the check box to 
disable it).
2. Click Save.
Note:
The Enable Automatic Power‐Up After Power Failure 
feature can only be enabled or disabled by a superuser.
Configuring the Global System Settings
User Guide—Spectra T950V Library
Default
0 (zero) minutes
(Disabled)
Cleared 
(Enabled)
Cleared 
(Disabled)
Selected 
(Enabled)
Cleared 
(Disabled)
102