Chapter 9 — Configuring and Using Media Lifecycle Management
When the PreScan process completes, the library stores the tape health 
information for the cartridge in the MLM database. It also writes the MLM 
data to the cartridge MAM. When the drive ejects the cartridge, the library 
returns it to its original slot.
Requirements for Use When using PreScan, make sure that you consider 
the following requirements:
Consideration
Updating MLM
Data on MAM
Drive Availability
Auto Drive Clean
Restrictions
Cleaning Partitions
U
P
S
SING
OST
This section provides detailed information about how PostScan operates, 
as well as prerequisites for using PostScan and performing manual 
PostScan operations.
PostScan is enabled and configured for each individual partition. PostScan does not
Important
operate until the PostScan option is selected and one or more triggers are specified for
the partition (see

Operational Overview

PostScan  —   e ither FullScan or QuickScan  —   p erforms a readability 
verification test to verify data integrity for all of the cartridges in the MLM 
database. FullScan uses a Global Spare drive assigned to the partition and 
QuickScan uses a drive in the partition or Global Spare drive assigned to the 
partition to check each cartridge in the partition for media errors that can 
impact the ability to restore the data. 
August 2019
Requirement
Updating the cartridge MAM requires the cartridge to be write‐enabled.
Important:
If a cartridge is write-protected when it is inserted into a drive, the
information about the cartridge is added to the MLM database, but the library
cannot update the MLM information on the cartridge's MAM.
The media discovery process loads the cartridges in the partition into the drives 
assigned to that partition. While in use for PreScan, host moves to the drives being 
used are delayed until the PreScan operation completes. Spectra Logic highly 
recommends that you perform the manual media discovery process when your 
storage management software is not accessing the library and the library is idle.
Auto drive clean operations do not start while PreScan is running on any 
partition that is associated with the cleaning partition. If a drive requires cleaning, 
wait until the PreScan operation is complete and then manually clean the drive.
The PreScan feature cannot be enabled for a cleaning partition and does not 
affect the operation of cleaning cartridges.
CAN
Enable and Configure MLM PreScan and PostScan on page 180
Note:
PostScan cannot be configured for use in the same partition as 
Spectra SKLM or KMIP encryption key management.