Chapter 4 — Configuring the Library
2. From the toolbar menu, select Configuration > Controllers to display
3. Identify the controller that you configured to provide the robotic
4. Click Failover next to the controller you want to be the primary
August 2019
the Controllers screen.
Figure 53 The Controllers screen before the failover
controller is selected.
control path in a partition (see Select the Robotic Control Path on
page 174). This controller is the primary controller in the failover pair.
If you have not yet configured partitions, identify two
Note:
controllers (RIM2s). Both controllers must be at the same
firmware version.
controller in the failover pair. The Controller Failover screen displays
with a list of the other RIM2s in the library that can be used as the
failover partner.
The component identifiers for the RIM2s show them as F‐QIPs.
Note:
See RIM2 Identifiers on page 58 for more information.
Figure 54 The Controller Failover screen.
Configuring Optional Library Settings
User Guide—Spectra T950V Library
121