ELETING A
Overview When you delete a partition, the drives and chambers 
previously assigned to that partition are available to be assigned to a new 
or existing partition.
Preparation Before deleting an existing partition, review the information 
at the beginning of this chapter to be sure that you address any 
requirements (see Partition Types and Requirements on page 161). In 
addition, make sure you address the following:
 Spectra Logic strongly recommends backing up the library 
 To ensure that you do not inadvertently mix cartridges from one 
After the partition is deleted, any magazines in the chambers that were assigned to
Important
the partition's storage and entry/exit pools are not accessible until the chambers
are assigned to another new or existing partition.
 If the storage partition is configured to use BlueScale encryption, make 
 If you plan to delete a cleaning partition, edit any storage partitions that 
Auto Configuration Save When you delete a partition, the library 
automatically generates a configuration backup file and saves it to the 
memory card in the LCM. If you configured the email option for the Auto 
Configuration Save file, an email with the backup file as an attachment is 
sent to the specified recipient (see Enable Email for the Auto Configuration 
Save File on page 109).
August 2019
ARTITION
configuration, either to a USB device or as an attachment to an email 
sent to a previously configured mail recipient, before you delete a 
partition.
storage partition with that from another, use your storage management 
software to eject all of the cartridges from the storage partition's storage 
pool. The library moves the media to the partition's entry/exit pool. 
Export the media from the library as described in Exporting or 
Exchanging Magazines and Cartridges on page 211.
sure that you export the BlueScale encryption key for any cartridges 
that were in the partition (see the Spectra Tape Libraries Encryption User 
Guide). The encryption key is required in order to access the data on the 
cartridges at a later date.
use the cleaning partition to unassociate the cleaning partition from the 
storage partition, otherwise, the delete fails.
Note:
Do not use the default autosupport@spectralogic.com email 
recipient. Spectra Logic does not save emailed configuration files 
unless they are specifically requested for troubleshooting.