Spectra Logic Spectra T950V User Manual page 182

Tape library
Hide thumbs Also See for Spectra T950V:
Table of Contents

Advertisement

Chapter 6 — Configuring and Managing Partitions
Option
Enable PreScan
FullScan
QuickScan
QuickScan using
Global Spares
PostScan Triggers
August 2019
 The following table describes the PreScan and PostScan options.
When selected...
Enables the PreScan feature. When enabled, PreScan replaces the 
more basic Media Auto Discovery process. See Using PreScan on 
page 266 for information about this option.
Enables the FullScan feature. When enabled by selecting one or 
more PostScan triggers, FullScan uses a Global Spare drive 
assigned to the partition to verify all of the data on each cartridge. 
See Using PostScan on page 267 for information about this option.
Note:
FullScan is only available if a Global Spare drive is 
configured for the partition.
Enables the QuickScan feature. When enabled by selecting one or 
more PostScan triggers, QuickScan uses one of the drives in the 
partition to verify the data on a single wrap, from the beginning 
of the tape (BOT) to the end of the wrap or the end of recorded 
data (EOD), whichever comes first. See Using PostScan on 
page 267 for information about this option.
Enables the QuickScan using Global Spares feature. When 
enabled by selecting one or more PostScan triggers, QuickScan 
uses a Global Spare drive assigned to the partition to verify the 
data on a single wrap, from the beginning of the tape (BOT) to the 
end of the wrap or the end of recorded data (EOD), whichever 
comes first. See Using PostScan on page 267 for information about 
this option.
Notes:
 QuickScan using Global Spares is only available if a Global 
Spare drive is configured for the partition.
 QuickScan using Global Spares is only available if the partition 
uses Fibre Channel drives.
Enables PostScan and configures one or more triggers.
 Verify After Time  —   A dd the cartridges in the partition to the 
automatic PostScan queue after the specified number of days 
pass since the last scan. Enter the number of days in the Days 
field.
 Verify After Write  —   A dd a cartridge to the automatic PostScan 
queue each time data is written to it.
 Verify After Read  —   A dd a cartridge to the automatic PostScan 
queue each time data is read from it.
Selecting any of these triggers automatically enables the 
Note:
selected PostScan option.
Creating a Storage Partition
User Guide—Spectra T950 Library
Default
Disabled 
(cleared)
Disabled 
(no 
PostScan 
triggers 
selected)
Disabled 
(no 
PostScan 
triggers 
selected)
Disabled 
(no 
PostScan 
triggers 
selected)
Disabled 
(cleared)
182