Chapter 12 — Library Troubleshooting
Issue
Cause
If the library loses power 
Cartridge left in a
during backup operations 
tape drive after a
or you reset or power‐
library power-
cycle the library without 
cycle or reset
first unloading all of the 
drives, cartridges may 
If the drive is a
remain in the drives.
Global Spare, see
Cartridge left in a
Global Spare tape
drive after a
library power-
cycle or reset
Cartridge left in a
If the library loses power 
Global Spare tape
or if you reset or power‐
drive after a
cycle the library while the 
library power-
PostScan process is 
cycle or reset
running, the cartridge 
being scanned remains in 
the drive. The library 
generates a message to 
notify you that the Global 
Spare contains a cartridge 
after it completes its 
initialization process.
August 2019
Resolution
CAUTION:
When the Unload Drives utility runs,
cartridges are unloaded from all drives in the
selected partition(s), even if they are active. This
could cause backups to fail. Do not use the
Unload Drives utility when file storage operations
are actively running.
1. From the toolbar menu, select Maintenance >
Tools. The Maintenance Tools screen displays.
2. Select Utilities. The Utilities screen displays.
3. Click Show Advanced. The Advanced Utilities 
Confirmation screen displays.
4. Click Next. The Utilities screen refreshes to show 
a list of the advanced utilities.
5. Scroll down and select Unload Drives.
6. From the Select the partition or library drop‐down 
list, select a partition or Total Library.
7. Click Run Utility.
8. A progress screen displays, all drives assigned to 
partitions in the full library or the selected 
partition are unloaded, and the cartridges are 
returned to their original slots or the first 
available slot if the original slot is not available. 
When the operation is complete, a Utility Results 
screen displays.
This utility does not unload cartridges from 
Note:
Global Spare tape drives being used for PostScan. If 
there is a cartridge left in a Global Spare tape drive, 
see Cartridge left in a Global Spare tape drive after a 
library power‐cycle or reset.
CAUTION:
Make sure the drive you are sparing is
not actively running a backup or restore
operation. This could cause backups to fail.
Use the following steps to return the cartridge to its 
storage location:
1. Examine the partition inventories to determine in 
which partition the cartridge belongs (see 
Viewing and Downloading the Cartridge 
Inventory on page 226).
2. Substitute the Global Spare tape drive containing 
the cartridge for another drive in the same partition 
(see Use the Global Spare Drive on page 356).
3. Move the cartridge out of the drive and return it 
to its storage location (see Moving Cartridges 
Within a Partition on page 233).
4. Return the drive back to Global Spare status. (see 
Undo the Global Spare Drive on page 359).
User Guide—Spectra T950V Library
Resolving Operational Issues
326