Chapter 11 — Configuring and Using AutoSupport
2. Click Configure Alarms from the AutoSupport screen. The AutoSupport 
3. Select Enable Critical AutoSupport Alarms. When enabled, the library 
4. If desired, select a value for the Partition Drive Failure Threshold from 
5. Click Save to save your changes or click Previous to return to the main 
6. Click Previous to return to the main AutoSupport screen. 
August 2019
Critical Alarm Configuration screen displays. 
Figure 168 The AutoSupport Critical Alarm Configuration
screen.
generates an ASL file whenever one of the critical events listed under 
Critical Alarms on page 301 occurs. Any ASL file that is generated as a 
result of a critical event is automatically sent to all of the recipients 
selected in the AutoSend profile.
Note:
The autosupport@spectralogic.com address must be selected as a 
mail recipient in the AutoSend profile if you want the library to 
send critical event ASL files to Spectra Logic Technical Support.
the drop‐down list. This is the only configurable critical event.
You can specify the threshold for the number of failed drives in a 
partition that causes an AutoSupport ticket request to be generated. 
The threshold is a percentage of drives assigned to the partition. You 
can select 25% or 50%; the default is 50%. The threshold applies to all 
partitions in the library.
AutoSupport screen without saving your changes.
After your changes are saved, the AutoSupport Critical Alarm 
Configuration screen redisplays with a confirmation message.