Chapter 14 — Maintaining the Library
Update using USB device
options selected
Update RCM controllers
using USB device selected
or
Update RIM2 controllers
using USB device selected
or
Both
3. When complete, the Package Update Results screen displays, showing that 
4. If you used a USB device during the update process, disconnect it.
August 2019
Update Process
The library starts the update wizard, which guides you through the 
update process. Based on your selections, the wizard instructs you to 
connect and remove the USB device from various components.
Notes:
 Each time you connect the USB device to a component, wait at least 10 
seconds for the USB device to mount, and then click Continue.
 If you do not respond to the Feedback Required screen within 10 
minutes, the request times out and the component update fails.
 Each component takes 5‐10 minutes to update.
If you selected both Update RCM controllers using USB device and 
Update RIM2 controllers using USB device, the process is as follows:
1. On the Feedback Required screen, confirm that you connected a USB 
device to a USB port on the LCM (in Step 2 on page 398). The library 
copies a file containing the appropriate RCM firmware to the device.
2. A Feedback Required screen prompts you to remove the USB device 
from the LCM and connect it to the specified RCM.
3. When the RCM update is complete, a Feedback Required screen 
prompts you to remove the USB device and connect it to the next 
RCM. This is repeated until all RCM control modules are updated.
4. When all of the RCM updates are complete, a Feedback Required 
screen prompts you to move the USB device back to the LCM. The 
library copies a file containing the appropriate RIM2 firmware to the 
USB device.
5. A Feedback Required screen prompts you to remove the USB device 
from the LCM and connect it to a RIM2. This is repeated until all RIM2 
controllers are updated.
the update completed successfully or that a component failed to update. 
If the update fails, examine any system messages and the 
Note:
package update log to determine the cause of the failure. Resolve 
the problems and perform the update again. For further 
information, see Troubleshooting below.
Updating the BlueScale Software and Library Firmware