Chapter 14 — Maintaining the Library
I
C
NSTALLING
Install the cord locks included with each frame to prevent the power cords 
from being inadvertently disconnected from the dual AC input connectors. 
1.
2. Discontinue all file storage operations to the library.
3. Power off the library (see Power Off the Library on page 144). 
4. Set the AC breaker switches on the dual AC module to the "off" 
5. If the power cords are plugged into wall plugs, unplug them. Also 
6. Using a #2 Phillips screwdriver, remove the two screws securing each 
7. Place a cord lock over the connector on the end of the power cord that 
8. Push the power cord into the input plug and reinstall the screws that 
August 2019
L
ORD
OCKS
Note:
The photos in this section show installing the cord locks on a 
dual AC power module. The parts and the procedure are the 
same for the dual AC with convenience outlet or the dual AC2 
power modules.
Pause PostScan if it is running (see Pause the PostScan Process on 
page 274). Any tapes currently being scanned are returned to their 
storage locations.
position.
unplug them from the dual AC module where you plan to install the 
cord locks.
of the two input plugs to the dual AC module (circled in Figure 235).
Figure 235 Remove the screws securing the input plugs to
the AC power module.
connects to the library. Orient the cord lock as shown in Figure 236.
Figure 236 Install the cord locks on the power cords.
secure the input plug to the dual AC module. Make sure that the cord 
connector is fully seated in the input plug. 
Cord lock
clamp screw