Determine the Cleaning Method

The method you use to clean the drive depends on the following factors:
If...
Auto Drive Clean is 
enabled and a cleaning 
partition is associated with 
the storage partition,
A cleaning partition is not 
associated with the storage 
partition; your software 
package includes features 
that allow for scheduled 
drive cleanings,
A cleaning partition is not 
associated with the storage 
partition and your 
software package does not 
have features that allow 
for scheduled drive 
cleanings,
A Global Spare drive 
requires cleaning and a 
cleaning partition is not 
present, 
August 2019
Then...
The library automatically cleans the drives, including any Global 
Spares, as needed. See Chapter 6 – Configuring and Managing 
Partitions, beginning on page 160 for information about configuring a 
cleaning partition and associating it with one or more storage partitions.
You can also clean the drive manually using a cleaning cartridge in the 
cleaning partition (see Cleaning Partition Present on page 419).
Use your storage management software to perform regularly scheduled 
drive cleanings. Refer to your storage management software user 
manual or vendor for instructions on how to set up scheduled 
automatic cleanings.
You may choose to leave a cleaning cartridge in each storage partition, 
particularly if you can configure your storage management software to 
perform regular automated cleanings.
Important:
Make sure that the cleaning cartridge has a barcode label.
Your software must be able to identify the cleaning cartridge and use it
only for cleaning drives. Any attempts to use a cleaning cartridge for
data storage causes backup failures.
Import a cleaning cartridge into the partition and clean the drive 
manually as described in No Cleaning Partition Present on page 420.
You may choose to leave a cleaning cartridge in each storage partition 
so that it is available whenever you need it.
Important:
Make sure that the cleaning cartridge has a barcode label.
Your software must be able to identify the cleaning cartridge and use it
only for cleaning drives. Any attempts to use a cleaning cartridge for
data storage causes backup failures.
Prepare and clean the drive as follows:
1. Pause the PostScan operation if it is using the Global Spare drive that 
needs cleaning (see Pause the PostScan Process on page 274).
2. Temporarily substitute the Global Spare drive for a drive in a 
partition that is associated with the Global Spare drive (see Use the 
Global Spare Drive on page 356).
3.
Clean the drive manually (see No Cleaning Partition Present on 
page 420).
4. Reclaim the Global Spare drive so that it is again available for use as a 
spare (see Undo the Global Spare Drive on page 359).