Update Using The Update Drive Firmware Utility - Spectra Logic Spectra T950V User Manual

Tape library
Hide thumbs Also See for Spectra T950V:
Table of Contents

Advertisement

Chapter 15 — Maintaining the Drives
6. Click Start Update to begin the background operation to update the 
7. If you need to change the library configuration, modify a partition, or 
8.
9. Use your storage management software to restart backup processes.

Update Using the Update Drive Firmware Utility

The Update Drive Firmware utility uses a firmware tape to update a single 
drive or all of the drives in a single partition. 
Requirements
 The drives to be updated must be configured in a storage partition.
 The firmware update tape must be in a magazine stored in the storage 
 The drives are updated one partition at a time.
 To update the firmware of a Global Spare, first substitute the Global 
August 2019
selected drives. The Drive Firmware Update screen refreshes to show 
that the update operation is running.
Figure 254 Drive Firmware Update screen showing an
update running.
After each drive is updated, the library posts a system message 
indicating whether or not the update was successful.
Note:
Once the update process begins, you cannot start any additional 
Drive Firmware Update operations until the currently running 
process either completes or is stopped. 
make other changes that are restricted while background operations are 
running, click Stop Update. The library completes any updates that are 
currently in progress and then returns the firmware tape to the magazine.
Export the firmware update tape from the library (see Exporting or 
Exchanging Magazines and Cartridges on page 211) and store it for 
future use.
Note:
You cannot use the Update Drive Firmware Utility to update a 
TS11xx technology drive.
partition's entry/exit pool. 
Note:
The partition must have entry/exit chambers configured to use 
this wizard.
Spare drive for a drive assigned to a partition. After the Global Spare 
drive completes the firmware update process, it can be removed from 
the partition and returned to the pool of spare drives (see Use the 
Global Spare Drive on page 356 for more information).
Updating Drive Firmware
User Guide—Spectra T950V Library
440