Resolving Operational Issues - Spectra Logic Spectra T950V User Manual

Tape library
Hide thumbs Also See for Spectra T950V:
Table of Contents

Advertisement

Chapter 12 — Library Troubleshooting
R
O
ESOLVING
This section provides information about potential issues you may 
encounter while operating the library.
Issue
Cause
When the library is 
One or more
repeatedly unable to 
chambers
insert a magazine into a 
marked as
chamber, it marks the 
unusable
chamber as unusable and 
posts a system message. 
Element
Installing additional 
addresses change
drives into a partially 
filled DBA, or removing 
after installing
drives from a DBA, may 
additional drives
cause the library to 
reassign element 
addresses. 
If the library loses power 
Magazine is in
while a TeraPack 
TAP after a power
magazine is in a TAP, the 
failure
library only identifies the 
magazine's presence in 
the TAP the next time 
media is imported or 
exported.
The library was unable to 
Magazine is left
insert the magazine into 
in transporter
its original chamber and 
following a move
no empty chambers are 
available. The library 
posts a system message 
and halts.
A blockage is preventing 
System message
the library from moving 
indicates that the
robotics are
the robotics.
blocked
August 2019
I
PERATIONAL
SSUES
Resolution
1. Open a support ticket describing the system 
message that was posted (see Opening a Support 
Ticket on page 450).
2. Continue using the library, keeping the following 
in mind:
 If the library has unassigned chambers, 
operation is not affected. However, if you create 
a new partition that uses the unassigned 
chambers, you are not able to load magazines 
into all of the chambers assigned to the 
partition.
 If all of the chambers in the library are assigned 
to partitions, the number of magazines that can 
be imported into the partitions is reduced.
To avoid errors after adding a new drive, make sure 
that you reconfigure the element addresses your 
storage management software uses to access drives 
when you install a new drive (refer to your software 
documentation for instructions).
To recover the magazine, use the Import/Export 
TeraPack Magazines screen to initiate an import or 
export operation (see Chapter 7 – Importing and 
Exporting Cartridges, beginning on page 198 for 
instructions).
Contact Spectra Logic Technical Support for 
assistance (see Contacting Spectra Logic on page 7).
Contact Spectra Logic Technical Support for 
assistance (see Contacting Spectra Logic on page 7).
User Guide—Spectra T950V Library

Resolving Operational Issues

325