Spectra Logic Spectra T950V User Manual page 372

Tape library
Hide thumbs Also See for Spectra T950V:
Table of Contents

Advertisement

Chapter 13 — Drive Troubleshooting
Code
DLM
Health
Icon
3
4
August 2019
Cause and Solution
Firmware problem.
Important:
Do not force a dump; one already exists.
The drive determined that a firmware error occurred. Perform the following:
If possible, use ITDT to collect the existing drive dump (see Use the IBM Tape 
1.
Diagnostic Tool (ITDT) to Retrieve a Drive Dump on page 362). 
If you cannot use ITDT, use the BlueScale Retrieve Drive Dump utility (see Use 
the BlueScale Retrieve Drive Dump Utility on page 363).
2. Reset the drive (see Resetting a Drive on page 354), then retry the operation 
that produced the error.
3. If the problem persists, contact Spectra Logic Technical Support and send the 
drive dump to them, if requested (see Contacting Spectra Logic on page 7).
Note:
The error code clears when you reset or power cycle the drive or when 
you place it in maintenance mode.
Firmware or drive problem.
Important:
Do not force a dump; one already exists.
A firmware or drive hardware failure occurred. Perform the following:
1.
If possible, use ITDT to collect the existing drive dump (see Use the IBM Tape 
Diagnostic Tool (ITDT) to Retrieve a Drive Dump on page 362). 
If you cannot use ITDT, use the BlueScale Retrieve Drive Dump utility (see Use 
the BlueScale Retrieve Drive Dump Utility on page 363).
2. Reset the drive (see Resetting a Drive on page 354), then retry the operation 
that produced the error.
3. If the problem persists, contact Spectra Logic Technical Support and send the 
drive dump to them, if requested (see Contacting Spectra Logic on page 7).
Note:
The error code clears when you reset or power cycle the drive or when 
you place it in maintenance mode.
Troubleshooting Drives
User Guide—Spectra T950V Library
372