Chapter 6 — Configuring and Managing Partitions
For this field...
EE Chambers
Drives
Cleaning Partition
August 2019
Do the following...
Enter the number of chambers to assign to the entry/exit pool for this partition.
Notes:
Some storage management software features require an entry/exit pool.
Spectra Logic recommends assigning at least one entry/exit chamber.
It is useful for the entry/exit pool to be larger than the expected import/export
operations you plan to do on a daily or weekly basis.
The cartridges stored in the entry/exit pool are not accessible to the storage
management software for writing or reading data.
Select the drives to be dedicated to this partition. The check boxes for any
installed drives that cannot be used in the partition are grayed out. Any drive
already selected as a controller is automatically selected and cannot be cleared.
Notes:
You cannot use Fibre Channel and SAS drives in the same partition.
If you enabled Global Spares (see Assign Global Spare Drives on page 176),
you can only select Fibre Channel drives of the same generation as the Global
Spare drive assigned to the partition.
If you plan to mix multiple generations of LTO cartridges in the same
partition, make sure that the drives in the partition are compatible with every
generation of data cartridge in the partition (see LTO Read/Write
Compatibility on page 494 for compatibility information).
Select the name of the cleaning partition to be used for the drives in the storage
partition. Associating a cleaning partition with the storage partition enables the
Auto Drive Clean feature for the partition. If you do not want to enable Auto
Drive Clean, select None.
The option to select a cleaning partition is only available if you previously
Note:
configured a cleaning partition that uses the same type of media as the storage
partition (see Creating a Cleaning Partition on page 167). If you create a cleaning
partition later, edit the storage partition to associate the cleaning partition with it.
Creating a Storage Partition
User Guide—Spectra T950 Library
179