Power On
until the button's LED illuminates. Wait while the library completes its power-on
P
sequence, which takes about five minutes depending on the library configuration.
OWERING
During the power-on sequence the library initializes all components.
L
THE
IBRARY
O
O
Power Off
N AND
FF
power button until the button's LED starts flashing (about 6 seconds). If the
button is not illuminated (but the library is running), log in as a superuser and
use the General Status screen soft power button. The power-off sequence takes
approximately one minute to allow applications to shut down gracefully.
Note:
If the library is experiencing problems, do not power it off unless
specifically directed to do so by Spectra Logic Technical Support.
Log Into the Library
2
screen displays.
If the pre-login General Status screen is displayed, click select here to
Note:
login at the bottom of the screen to display the Login screen.
1.Using the stylus, touch (to select) the User box and enter the user name.
L
OGGING
2.If you configured a password for the user entered in
I
NTO AND
select the Password box and enter the password. Then click Login.
O
UT OF THE
If you have not configured a password—leave the password field blank,
U
SER
and click Login.
I
NTERFACE
3.Wait for the initialization process to complete.
4.Close the keyboard by selecting its icon with the stylus.
Log Out of the Library
log out and re-display the login screen.
The library's user interface lets you set configuration options, view library and
3
drive information and metrics, manage media, and monitor library operations.
Toolbars
expands it to display the available options within that menu. The General
toolbar accesses the most frequently used library screens and controls:
U
 General Status—Displays the current status for all of the major library
SING THE
B
S
components for the selected library partition.
LUE
CALE
 Inventory—Displays controls for viewing the library's media inventory
I
NTERFACE
and for moving media from one location in the library to another.
 Import/Export—Displays controls for importing and exporting media.
 Metrics—Displays metrics for tape drive performance, power
consumption, and storage density for the media types in the library.
 Media Lifecycle Management—Displays options for generating and
viewing Media Lifecycle Management reports.
Status Bar
 Refresh Button—Refreshes (updates) the information currently
displayed on the user interface.
 Messages & Feature Icons—Indicate the status of library components, as
described in the table to the right. Additional icons provide access to Remote
Support or Package Update, if applicable.
 Last Refreshed—Shows the time of the last screen refresh.
 Current BlueScale Software Version—Shows the version of the BlueScale
software currently running on the library.
 Networking Icon or Library Name —Shows the Network Settings icon (on
the touch screen) or the library's name, if set (when using the BlueScale web
interface).
Keyboard Options
requires a keyboard. You can use any of these keyboard options:
 Soft Keyboard—When using the touch screen, use the stylus to
select the keyboard icon in the lower right corner of the screen to
activate the on-screen keyboard.
 BlueScale Web Interface—You can connect the library to an
Ethernet network and access the user interface through the BlueScale web
interface using a standard web browser.
I
MPORTANT
do not use the Enter key on your keyboard when entering information in any
of the text fields. Always click the on-screen buttons in BlueScale screens
instead of using your keyboard.
 External Keyboard—You can connect a USB keyboard and mouse directly to
the LCM.
I
MPORTANT
keyboard. Use only the characters that appear on the soft keyboard.
S
PECTRA
Q
R
UICK
Spectra T950V Library User Guide
for detailed library information.
Press and hold the front panel power button for several seconds
If the power button is illuminated, press and hold the front panel
After the power-on sequence completes, the Login
From the Security screen, select Switch User to
Selecting a toolbar along the left side of the screen
The status bar is located at the bottom of the screen.
Entering information into a library screen
When accessing the library remotely through a web browser,
Do not use special characters when using an external
© 2018 ArcticBlue, BlackPearl, BlueScale, CC, Spectra, SpectraGuard, Spectra Logic, TeraPack, TFinity, TranScale, and Verde are registered trademarks of Spectra Logic Corporation. SeeVault and Eon
Protect are trademarks of Spectra Logic Corporation. All rights reserved worldwide. All other trademarks and registered trademarks are the property of their respective owners
T950 L
IBRARY
G
EFERENCE
UIDE
at
Touch screen
user interface
1
2
3
Step
1, use the stylus to
4
Users are divided into the following types.
 Superuser—Controls all aspects of library use and configuration.
 Administrator—Configures the library and runs diagnostics. The
 Operator—Performs tape handling operations. The default user
The default password is blank.
Current
toolbar
Additional
toolbars
Refresh
Status bar
Icon Meaning
Soft keyboard—Use the keyboard to enter values in the user
interface.
Soft keyboard icon
Soft keyboard opened
Stylus—Use the stylus to open and close the keyboard, type the
values, and click ENTER to complete the process.
Power button
Type user name
Type password
and click Login
Wait
Close keyboard
The default user name for this group is su.
default user name for this group is administrator.
name for this group is operator.
System OK—All system components are functioning
correctly.
Information—An informational message about a component
is available. Check messages to determine the component.
Attention—A system component requires attention. Check
messages to determine the component.
Error—A system component has experienced an error
condition. Check messages to determine the component.
HHM Notification—A component has reached its maintenance
threshold. Click the icon to view the Hardware Health Monitoring
notification and generate an AutoSupport ticket.
Touch the icon with the stylus
to open or close the keyboard.
Touch the icon with the stylus
to switch between letters and
numbers.

Advertisement

loading

Summary of Contents for Spectra Logic T950v

  • Page 1 Use only the characters that appear on the soft keyboard. © 2018 ArcticBlue, BlackPearl, BlueScale, CC, Spectra, SpectraGuard, Spectra Logic, TeraPack, TFinity, TranScale, and Verde are registered trademarks of Spectra Logic Corporation. SeeVault and Eon Protect are trademarks of Spectra Logic Corporation. All rights reserved worldwide. All other trademarks and registered trademarks are the property of their respective owners...
  • Page 2 Expand and Upgrade Your Library You can purchase expansion and upgrade options either separately or when you order the library by contacting a Spectra Logic sales representative (see below). You can also purchase selected items from our online store at shop.spectralogic.com. OCATING Read Product Documentation View these resources at www.spectralogic.com/documents.