Chapter 4 — Configuring the Library

Configure Barcode Reporting

Overview The Spectra Logic tape libraries support barcode data strings 
consisting of a start character; from 1 to 16 characters, including 
alphanumeric characters and an optional checksum character; and the stop 
character. Quiet zones precede and follow the start and stop characters.
By default, the library:
 Expects barcode labels with checksums (that is, it treats the right‐most 
 Does not use the checksum character to validate the barcode.
 Reports up to 16 characters but does not report the checksum character.
Modifying Barcode Reporting If your environment has any of the 
following:
 Labels without a checksum character
 A requirement to validate the barcode using the checksum
 Storage management software with specific barcode requirements
then you may need to modify the default settings used by the library.
Important
August 2019
character as a checksum character).
Note:
With the exception of the checksum, the barcode labels typically 
show the human‐readable character that each barcode character 
represents. The checksum character is not considered 
human‐readable.
Proceed with caution when changing the library's default barcode reporting
settings. Any changes that you make affect every partition in the library. Before
making changes, make sure that the changes do not adversely affect others
using the library.
If you modify the barcode reporting settings, you should do so before using any
cartridges in the library. If you change the barcode reporting settings after the
cartridges were used by the storage management software, the software may
no longer recognize those cartridges. In general, it is best to leave the library set
to its defaults and make any reporting modifications on the software side if that
is an option.
Never mix cartridges with checksummed and non-checksummed labels in the
library.