Spectra Logic Spectra T950V User Manual page 149

Tape library
Hide thumbs Also See for Spectra T950V:
Table of Contents

Advertisement

Chapter 5 — Operating the Library
Use Syslog
The BlueScale Syslog feature sends all system messages logged by the 
library to a previously configured Syslog server. Syslog is a standard for 
forwarding log messages over an Internet Protocol (IP) computer network. 
It provides separation of the software that generates log messages from the 
system that stores the messages.
Each system message the library sends to the Syslog server contains the 
original system message posted by the library and the remedy information 
associated with the system message.
See Syslog Server IP Address on page 104 for information about entering 
the IP address of the Syslog server. Entering a valid IP address enables the 
Syslog feature.
When enabled, the BlueScale Syslog feature automatically sends all system 
messages posted by the library to a single, previously configured Syslog 
server. The library transmits the messages to the Syslog server using the 
format: 
<severity level>BlueScale_<library name>[PP]:(<message number>)
<message text>
where: 
Variable
severity level
library name
PP
message number
message text
August 2019
Definition
Indicates the severity the library assigned to the message. This severity 
corresponds to the syslog priorities as follows:
This library system message severity...
Informational
Warning
Error
Fatal Error
The name of the library, if configured. If the library name is not configured, this 
value is set to "UnknownLibrary."
Refer to Library Name on page 101 for information about setting the library 
name.
Indicates the ID number of the process that was being performed by the 
library's BlueScale software when the system message was posted. This ID 
number is for internal use only.
Indicates the order in which the Syslog server received the messages. The counter 
increments each time a message is received, beginning at zero. The counter can be 
used to determine whether all messages are arriving at the Syslog server.
Shows the actual message posted by the library. Each system message posted by 
the library generates two Syslog messages; one for the message text and one for 
the remedy text. The two messages have the same message number, which is 
included at the beginning of the message.
Monitoring Your Library
Corresponds to this Syslog priority...
6 (Informational)
4 (Warning)
3 (Error)
2 (Critical)
User Guide—Spectra T950V Library