Chapter 1 — Library Overview
Component
Dual AC 2 Power
Module
Media Expansion Frames
Media expansion frames are for media storage only and do not include any
active front or rear panel components. See Data Storage Capacity on
page 477 for more information.
August 2019
Description
The dual AC 2 power module provides surge protection for the library power
system and monitors the primary AC input power to determine whether it is
present and of adequate voltage. If the primary AC input fails or drops too low,
the dual AC 2 power module handles the failover to the redundant, secondary
AC input until the primary input is restored.
Each dual AC 2 power module includes both primary and secondary AC power
connectors, two breaker switches, and a convenience outlet rated at 2 amps.
LEDs indicate the status of the primary and secondary AC inputs and the
overall dual AC 2 module.
Primary and Secondary Input Power LED States:
Green ‐ Good/Active
Blue ‐ Good/Not Active
Orange ‐ Bad/Active, cannot switch to secondary source
Red ‐ Under Voltage Lockout
Off ‐ Not Present
Dual AC 2 Status LED States:
Blinking Green ‐ Good Status
Solid Red ‐ Over Temperature, > 100° C
The convenience outlet is powered by the primary AC input. If the
Note:
primary input fails, the convenience outlet does not function.
Convenience outlet
Secondary AC breaker,
and fuse
input, and status LEDs
Figure 6 Dual AC 2 power module.
Primary AC breaker,
input, and status LEDs
User Guide—Spectra T950V Library
Library Features
37