Chapter 1 — Library Overview
Component
Dual AC 2 Power
Module

Media Expansion Frames

Media expansion frames are for media storage only and do not include any 
active front or rear panel components. See Data Storage Capacity on 
page 477 for more information.
August 2019
Description
The dual AC 2 power module provides surge protection for the library power 
system and monitors the primary AC input power to determine whether it is 
present and of adequate voltage. If the primary AC input fails or drops too low, 
the dual AC 2 power module handles the failover to the redundant, secondary 
AC input until the primary input is restored. 
Each dual AC 2 power module includes both primary and secondary AC power 
connectors, two breaker switches, and a convenience outlet rated at 2 amps. 
LEDs indicate the status of the primary and secondary AC inputs and the 
overall dual AC 2 module.
 Primary and Secondary Input Power LED States:
 Green ‐ Good/Active
 Blue ‐ Good/Not Active
 Orange ‐ Bad/Active, cannot switch to secondary source
 Red ‐ Under Voltage Lockout
 Off ‐ Not Present
 Dual AC 2 Status LED States:
 Blinking Green ‐ Good Status
 Solid Red ‐ Over Temperature, > 100° C
The convenience outlet is powered by the primary AC input. If the 
Note:
primary input fails, the convenience outlet does not function. 
Convenience outlet
Secondary AC breaker,
and fuse
input, and status LEDs
Figure 6 Dual AC 2 power module.
Primary AC breaker,
input, and status LEDs
User Guide—Spectra T950V Library
Library Features
37