Chapter 13 — Drive Troubleshooting
 If a cleaning partition is associated with the partition containing the 
When importing a cleaning cartridge into the partition's entry/exit pool, it must be
Important
in a regular TeraPack magazine; it cannot be in a Maintenance TeraPack magazine.
 Only a user with superuser or administrator privileges can perform a 
August 2019
drive, make sure the cleaning partition contains a cleaning cartridge 
with Good (green) or Usable health. You can use MLM to determine the 
health of the cleaning cartridges currently in the cleaning partition (see 
Generate MLM Reports on page 275). If necessary, import a known 
good cleaning cartridge into the cleaning partition (see Importing into a 
Storage or Cleaning Partition on page 204).
If the partition does not use a cleaning partition, a cleaning cartridge 
with Good or Usable health must be in the partition's entry/exit pool. 
Import a known good cleaning cartridge into the entry/exit pool (see 
Importing into a Storage or Cleaning Partition on page 204). 
 Both the scratch tape and the cleaning cartridge can be 
Notes:
imported into the entry/exit pool in the same magazine.
 The test aborts (fails) if the cleaning cartridge health is not 
Good or Usable.
 The cleaning cartridge must have a barcode label.
 If the entry/exit pool contains only one chamber, both the 
cleaning cartridge and the scratch cartridge must be in the 
same magazine.
DLM Drive Health test. See Understanding User Groups and Security 
on page 91 for information about the three types of user groups and 
what types of privileges each has.