Troubleshooting Bluescale User Interface Issues - Spectra Logic Spectra T950V User Manual

Tape library
Hide thumbs Also See for Spectra T950V:
Table of Contents

Advertisement

Chapter 12 — Library Troubleshooting
T
ROUBLESHOOTING
This section provides information about potential issues that you may 
experience while using the library's BlueScale user interface, either from 
the operator panel or through the web interface (RLC). 
Issue
BlueScale screens
exhibit display
problems
Cannot access the
library using the
BlueScale web
interface (RLC)
Cannot change a
configuration
setting
August 2019
B
S
LUE
CALE
Resolution
Occasionally, the BlueScale interface may exhibit display problems (for 
example, one screen displays on top of another or there are multiple toolbars), 
either in the operator panel user interface or through the web interface.
Click the refresh display button (
Important:
If you have a keyboard connected to the LCM or if you are
accessing the library through the BlueScale web interface, do not use the
keyboard to refresh the screen (for example, by pressing F5). Doing so may
cause unpredictable results.
 Make sure that the library is connected to the network via an Ethernet cable 
connected to the left most Ethernet port on the LCM. The right‐most Ethernet 
port on the LCM is a dedicated EtherLib port. (see Figure 9 on page 40).
 Make sure that the web server port is correctly configured for your 
environment (see Web Server Port on page 101).
Make sure that an IP address is configured for the library (see Configure 
Network Settings on page 105).
 If SSL is enabled for the library, make sure that you enter the IP address using 
the form: 
https://[library IP address]. 
See Connecting to the library remotely using the BlueScale web interface on 
page 85 for additional information.
Reset the LCM to make sure that the Ethernet port is not hung (see Reset the 
LCM or RCM on page 337).
Before attempting to change configuration settings:
 Recommended  —   M ake sure that the drives in the partition are empty.
 Make sure that the host is not communicating with the library.
 Make sure that no background processes are running (for example, Media 
Auto Discovery, PreScan, or PostScan). If a background process is running, 
the library displays a message indicating what it is.
 If the background process is Media Auto Discovery, PreScan, or PostScan 
and you cannot wait for the process to complete, you can stop or pause the 
operation (Stop the Discovery Process on page 266 and Pause the PostScan 
Process on page 274). 
 For all other background processes, wait until the process is completed and 
then retry the configuration change.

Troubleshooting BlueScale User Interface Issues

U
I
SER
NTERFACE
) on the status bar to refresh the screen.
User Guide—Spectra T950V Library
I
SSUES
319