SORTER> FUNCTION
TRM-SENS
Adj of trimmer dust sensr output: Fin-AG
Lv.1 Details
On the saddle unit, output of saddle dust sensor is automatically
adjusted.
Use case
• At the installation of trimmer
• At the replacement of trimmer dust sensor
• At the replacement of saddle controller PCB
Adj/set/operate method Select the item and press OK key.
IS-CON
DC Controller PCB RAM clear: Inserter
Lv.1 Details
To execute the RAM clear of Inserter DC Controller PCB to delete all
the adjustment contents and counter information.
Adj/set/operate method Select the item and press OK key.
8
Service Mode > SORTER > OPTION
T-8-113
8
Service Mode > SORTER > OPTION
OPTION
SORTER> OPTION
BLNK-SW
Saddle finisher fold pstn margin: Fin-AF
Lv.1 Details
To set the margin width in fold position of saddle finisher.
Use case
When changing the margin width of fold position
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power.
Display/adj/set range
0 to 2
0: Normal, 1: Wider, 2: Entire image (no margin)
Default value
2
MD-SPRTN
Function rstrct at finishr error: Fin-AF
Lv.1 Details
To set whether to stop the host machine at finisher error or not.
Use case
When not to stop the host machine at finisher error occurrence
Adj/set/operate method 1) Enter the setting value and press OK key.
2) Turn OFF/ON the main power.
Caution
When "1" (function restriction) is set, staple operation or alignment
operation is not executed. Set "0" at normal status.
Display/adj/set range
0 to 1
0: Normal, 1: function restriction
Default value
0
CNTR-OUT
Set of center positn delivery at stacker
Lv.2 Details
To set whether to use the center position delivery when the stacker is
used.
When 1 is set, shift delivery is not executed but the center position
delivery is excited.
Use case
Upon user's request (when they do not want to execute shift
delivery.)
Caution
This can be enabled when the stacker is connected.
Display/adj/set range
0 to 1
0: Not execute, 1: Execute
Default value
0