■ PRDC-1
COPIER> COUNTER> PRDC-1
PRM-WIRE
Primary charge wire parts counter: right
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
Supplement/memo
This is commonly used as operator maintenance parts counter.
PO-WIRE
Pre-prmry trns charge wire parts counter
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PRM-WIR2
Primary charge wire parts counter: left
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PR-WI-U1
Pri charge wire right unit parts counter
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
8
Service Mode > COPIER > COUNTER > PRDC-1
8
Service Mode > COPIER > COUNTER > PRDC-1
COPIER> COUNTER> PRDC-1
PR-WI-U2
Pri charge wire left unit parts counter
Lv.1 Details
Drawer connector(housing), Drawer connector(socket)
1st line: total counter value from the previous replacement
2nd line: Estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
Supplement/memo
This is commonly used as operator maintenance parts counter.
PRM-F-K2
Pri chrg wire pad holder prts cntr: left
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PRM-S-K2
Pri charge wire slider parts contr: left
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
PO-WI-U
Pre-pri trns chrg wire unit parts countr
Lv.1 Details
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
8-330
8-330