■ H-DRBL-1
COPIER> COUNTER> H-DRBL-1
LS-UNIT
Laser scanner unit parts counter
Lv.1 Details
Target parts: Laser scanner unit
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement. press OK key.
Display/adj/set range
0 to 99999999
Appropriate target value 0
TCL-CLT
Transfer cleaning clutch parts counter
Lv.1 Details
Target parts: Transfer cleaning clutch (CL1)
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Appropriate target value 0
PK-A-MR
Process unit motor parts counter
Lv.1 Details
Target parts: Primary charging assembly cleaning motor (M4), pre-
primary transfer charging assembly cleaning motor (M77)
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Appropriate target value 0
DEV-A-MR
Develop stirring parts counter
Lv.1 Details
Target parts: Developing stirring motor (M2)
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Appropriate target value 0
8
Service Mode > COPIER > COUNTER > H-DRBL-1
8
Service Mode > COPIER > COUNTER > H-DRBL-1
COPIER> COUNTER> H-DRBL-1
DRM-SNS
Drum potential sensor parts counter
Lv.1 Details
Target parts: Drum potential sensor (DP1)
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Appropriate target value 0
PREX-LED
Pre-exposure LED parts counter
Lv.1 Details
Target parts: Pre-exposure LED1 (LED1), pre-exposure LED2 (LED2)
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Appropriate target value 0
PFUS-BLT
Pre-fixing feed belt parts counter
Lv.1 Details
Target parts: Pre-fixing feed belt (4 sheets)
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Appropriate target value 0
PU-FD-BT
Suction belt parts counter
Lv.1 Details
Target parts: Suction belt
1st line: total counter value from the previous replacement
2nd line: estimated life
Use case
When checking the consumption level of parts or replacing the parts.
Adj/set/operate method To clear the counter value: Select the item and press the Clear key.
To change the estimated life: Select the item, enter the value and
press OK key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Appropriate target value 0