FUNCTION (Operation / Inspection Mode)

■ INSTALL
COPIER> FUNCTION> INSTALL
TONER-S
Toner supply to developing assembly
Lv.1 Details
Simultaneously execute a series of operations (driving of the
developing sleeve/toner stirring feed subpart/drum/ITB, and
developing bias output) necessary to supply toner to the developing
assembly/toner supply unit.
The operations automatically stop after countdown of 600 seconds.
Use case
• At the time of installation
• At the time of replacement of the developing assembly
• At the time of replacement of toner in the developing assembly
Adj/set/operate method 1) Select the item.
"Check the Developer" is displayed.
2) Check the connection and press the OK key.
The operations automatically stop after 10 minutes.
Caution
• Although "Check the Developer" is displayed when selecting the
item, be sure to check the connection between the developing
assembly and connector in advance.
• When a failure occurs, the operations can be manually stopped by
pressing the OK key.
Display/adjust/set range During operation: xxx sec (residual time), At the end of operation:
END
Default value
600
Required time
10 minutes
STRD-POS
Scan position auto adj in DADF mode
Lv.1 Details
Automatically adjust the DADF scanning position.
Use case
At the time of DADF installation/uninstallation
Adj/set/operate method 1) Enter the setting value and press the OK key.
The operation automatically stops after the adjustment is made.
2) Write down the value displayed by COPIER>ADJUST>ADJ-
XY>STRD-POS in the service label.
Caution
Write down the adjusted value in the service label.
Display/adjust/set range When the operation finished normally: OK, When the operation
failed: NG
Required time
Approx. 10 seconds
Related service mode
COPIER> ADJUST> ADJ-XY> STRD-POS
8
Service Mode > COPIER > FUNCTION (Operation / Inspection Mode) > INSTALL
8
Service Mode > COPIER > FUNCTION (Operation / Inspection Mode) > INSTALL
COPIER> FUNCTION> INSTALL
CARD
Card number setting
Lv.1 Details
Set the card number used for the card reader.
A series of numbers from the entered number to the number of cards
specified by CARD-RNG can be used.
Use case
• At the time of installation of the card reader
• After replacement of the HDD
Adj/set/operate method 1) Enter the number and press the OK key.
2) Turn OFF/ON the main power.
Caution
The card management information (department ID and password) is
initialized.
Display/adjust/set range 0 to 2001
Default value
0
Related service mode
COPIER> OPTION> FNC-SW> CARD-RNG (Level 2)
AINR-OFF
ON/OFF of initial rotation deactivation
Lv.1 Details
Set ON/OFF to disable execution of multiple initial rotations.
Multiple initial rotations can be omitted when turning OFF/ON the
power to check the image, etc. after the adjustment of multiple initial
rotations, etc. This mode is executed when multiple initial rotations
are not needed.
Use case
• At the time of installation
• At the time of replacement of the developing assembly
Adj/set/operate method 1) Enter the setting value and press the OK key.
2) Turn OFF/ON the main power.
Caution
Be sure to enable the operation (cancel disabling) before the
machine is used by the user. The operation is automatically enabled
by executing TONER-S.
Display/adjust/set range 0: OFF (Multiple initial rotations enabled), 1: ON (Multiple initial
rotations disabled)
Default value
0
Related service mode
COPIER> FUNCTION> INSTALL> TONER-S
E-RDS
Set use/no use of embedded-RDS function
Lv.1 Details
Set whether or not to use the Embedded-RDS function.
Use case
At the time of using Embedded-RDS
Adj/set/operate method 1) Enter the setting value and press the OK key.
2) Turn OFF/ON the main power.
Caution
Be sure to use E-RDS, RGW-PORT, COM-TEST, COM-LOG, and
RGW-ADR as a set.
Display/adjust/set range 0: Do not use the function, 1: Use the function (Send all the counter
information.)
Default value
0
Related service mode
COPIER> FUNCTION> INSTALL> RGW-PORT, COM-TEST, COM-
LOG, RGW-ADR
Supplement/memo
Embedded-RDS: Function to send device information such as the
device counter, failure, and consumables to the sales company's
server via SOAP protocol