Canon imagePRESS 1135 Series Service Manual page 1231

Hide thumbs Also See for imagePRESS 1135 Series:
Table of Contents

Advertisement

COPIER > OPTION > USER
BCNT-AST
Set box print ccount target job
Lv.1 Details
Setting the type of job that advances the count in box print with NE
controller (ASSIST).
Use case
When switching the type of job that is subject to counting of the box
print with NE controller.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: PDL job, 1: Copy job
Default value
0
PRJOB-CP
Set of count TX at RX print/report print
Lv.2 Details
Setting to enable/disable a page-basis count pulse transmission to
the charging management device at the time of reception print or
report print.
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: No transmission, 1: Transmission
Default value
0
Supplement/memo
Charging management device: Coin manager, Non-Canon-made
control card
DOC-REM
Dspl/hide of original removal message
Lv.1 Details
Setting to display/hide a message to remove original when scanning
with DADF without opening/closing DADF after scanning with the
copyboard.
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: Hide (no display), 1: Display
Default value
0
Supplement/memo
Only when DADF (option) is installed.
DPT-ID-7
Password entry set at dept ID rgst/auth
Lv.2 Details
Setting whether to require a password entry at the time of
registration/authentication of department ID.
With the setting to require entry, entry of 7-digit password is required
as well as entry of department ID.
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: Department ID only, 1: 7-digit (password) entry
Default value
0
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
8
Service Mode > COPIER > OPTION (Mechanical specifications Setting Mode) > USER
COPIER > OPTION > USER
RUI-RJT
Conect set at invalid auth from remoteUI
Lv.2 Details
Setting to cut connection of HTTP port when the machine receives
invalid authentication from remote UI for 3 times.
Use case
Upon request from the user
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: Continue connection, 1: Cut connection
Default value
0
CTM-S06
Set of password erase from export file
Lv.2 Details
Setting to delete password for file transmission address from export
file.
With the setting to delete password, the password of file transmission
target is deleted at the time of export of address book data from
remote UI.
Use case
Upon request from the user
To avoid information leak.
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Display/adj/set range
0 to 1
0: Keep password, 1: Delete password
Default value
0
FREG-SW
Dspl/hide of MEAP cuntr free regstr area
Lv.2 Details
Setting to display/hide free register area of MEAP counter for SEND
Use case
At the time of trouble analysis
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF and then ON the main power supply.
Caution
• Do not use this mode under normal servicing
• Be sure to follow instruction from the quality support department
when using this mode.
Display/adj/set range
0 to 1
0: Hide (no display), 1: Display
Default value
0
Supplement/memo
Individual count-up (counter advance) of MEAP application is
available for the free register area of MEAP counter.
8-288