Renesas F-ZTAT H8 Series Hardware Manual page 781

Hide thumbs Also See for F-ZTAT H8 Series:
Table of Contents

Advertisement

SSR—Serial Status Register
Bit
TDRE
Initial value
Read/Write
R/(W)
Parity error
0
[Clearing conditions]
• Reset or transition to standby mode.
• Read PER when PER = 1, then write 0
in PER.
1
[Setting condition]
Parity error: (parity of receive data does
not match parity setting O/E bit in SMR)
Framing error (for SCI0)
0
[Clearing conditions]
• Reset or transition to standby mode.
• Read FER when FER = 1, then write 0 in FER.
1
[Setting condition]
Framing error (stop bit is 0)
Receive data register full
0
[Clearing conditions]
• Reset or transition to standby mode.
• Read RDRF when RDRF = 1, then write 0 in
RDRF.
• The DMAC reads data from RDR.
1
[Setting condition]
Serial data is received normally and transferred
from RSR to RDR
Transmit data register empty
0
[Clearing conditions]
• Read TDRE when TDRE = 1, then write 0 in TDRE.
• The DMAC writes data in TDR.
1
[Setting conditions]
• Reset or transition to standby mode.
• TE is 0 in SCR
• Data is transferred from TDR to TSR, enabling new
data to be written in TDR.
Note: Only 0 can be written, to clear the flag.
*
7
6
5
RDRF
ORER
1
0
0
R/(W)
R/(W)
*
*
Multiprocessor bit
0
Multiprocessor bit value in
receive data is 0
1
Multiprocessor bit value in
receive data is 1
Appendix B Internal I/O Register
4
3
FER/ERS
PER
0
0
R/(W)
R/(W)
*
*
*
Transmit end
0
[Clearing conditions]
• Read TDRE when TDRE = 1, then write 0 in TDRE.
• The DMAC writes data in TDR.
1
[Setting conditions]
• Reset or transition to standby mode.
• TE is cleared to 0 in SCR and FER/ERS is
cleared to 0.
• TDRE is 1 when last bit of 1-byte serial character
is transmitted.
Error signal status (for smart card interface)
0
[Clearing conditions]
• Reset or transition to standby mode.
• Read ERS when ERS = 1, then write 0 in ERS.
1
[Setting condition]
A low error signal is received.
Overrun error
0
[Clearing conditions]
• Reset or transition to standby mode.
• Read ORER when ORER = 1, then write 0 in
ORER.
1
[Setting condition]
Overrun error (reception of next serial data
ends when RDRF = 1)
Rev. 3.00 Mar 21, 2006 page 753 of 814
H'B4
2
1
TEND
MPB
MPBT
1
0
R
R
R/W
Multiprocessor bit transfer
0
Multiprocessor bit value in
transmit data is 0
1
Multiprocessor bit value in
transmit data is 1
REJ09B0302-0300