Renesas F-ZTAT H8 Series Hardware Manual page 764

Hide thumbs Also See for F-ZTAT H8 Series:
Table of Contents

Advertisement

Appendix B Internal I/O Register
TOCR—Timer Output Control Register
Bit
7
Initial value
1
Read/Write
External trigger disable
0 Input capture A in channel 1 is used as an external trigger signal in
reset-synchronized PWM mode and complementary PWM mode
1 External triggering is disabled
Note: * When an external trigger occurs, bits 5 to 0 in TOER are cleared to 0, disabling ITU
output.
Rev. 3.00 Mar 21, 2006 page 736 of 814
REJ09B0302-0300
6
5
1
1
Output level select 3
0 TIOCB , TOCXA , and TOCXB outputs are inverted
3
1 TIOCB , TOCXA , and TOCXB outputs are not inverted
3
Output level select 4
0 TIOCA , TIOCA , and TIOCB outputs are inverted
3
4
1 TIOCA , TIOCA , and TIOCB outputs are not inverted
3
4
H'91
4
3
XTGD
1
1
R/W
4
4
4
4
4
4
ITU (all channels)
2
1
0
OLS4
OLS3
1
1
1
R/W
R/W
*