Renesas F-ZTAT H8 Series Hardware Manual page 505

Hide thumbs Also See for F-ZTAT H8 Series:
Table of Contents

Advertisement

• Receiving Multiprocessor Serial Data
Figure 13.12 shows a sample flowchart for receiving multiprocessor serial data and indicates
the procedure to follow.
Initialize
Start receiving
Set MPIE bit to 1 in SCR
Read ORER and FER flags in SSR
FER ∨ ORER = 1
Read RDRF flag in SSR
No
RDRF = 1?
Read receive data from RDR
No
Own ID?
Read ORER and FER flags in SSR
FER ∨ ORER = 1
Read RDRF flag in SSR
RDRF = 1?
Read receive data from RDR
No
Finished receiving?
Clear RE bit to 0 in SCR
Figure 13.12 Sample Flowchart for Receiving Multiprocessor Serial Data (1)
1
2
Yes
No
3
Yes
Yes
Yes
No
No
Yes
No
Yes
(continued on next page)
End
Section 13 Serial Communication Interface
1. SCI initialization: the receive data
function of the RxD pin is selected
automatically.
2. ID receive cycle: set the MPIE bit to 1
in SCR.
3. SCI status check and ID check: read
SSR, check that the RDRF flag is set
to 1, then read data from RDR and
compare with the processor's own ID.
If the ID does not match, set the MPIE
bit to 1 again and clear the RDRF flag
to 0. If the ID matches, clear the RDRF
flag to 0.
4. SCI status check and data receiving:
read SSR, check that the RDRF flag is
set to 1, then read data from RDR.
5. Receive error handling and break
detection: if a receive error occurs,
read the ORER and FER flags in SSR
to identify the error. After executing the
necessary error handling, clear the
ORER and FER flags both to 0.
Receiving cannot resume while either
the ORER or FER flag remains set to
1. When a framing error occurs, the
RxD pin can be read to detect the
break state.
4
5
Error handling
Rev. 3.00 Mar 21, 2006 page 477 of 814
REJ09B0302-0300

Advertisement

Table of Contents
loading

Table of Contents